Pump Head Calculation Excel Sheet -
Pump head (total dynamic head, TDH) is the total energy that a pump must impart to the fluid to move it from suction to discharge. It is expressed in meters (or feet) of liquid column.
( H = H_static + H_friction + H_velocity + H_pressure ) pump head calculation excel sheet
h_fittings = (K_elbow * n_elbow + K_valve * n_valve) * v²/(2g) Total friction head = pipe loss + fittings loss TDH = H_static + H_friction_total + H_velocity (if any) Section 7: Output & Results | Description | Value | Unit | |-------------|-------|------| | Static head | 33.19 | m | | Suction friction | 0.85 | m | | Discharge friction | 12.40 | m | | Total pump head | 46.44 | m | | Required hydraulic power | (Q * TDH * ρ * g)/3600000 | kW | Pump head (total dynamic head, TDH) is the
Friction factor (Swamee-Jain): =0.25/(LOG10(D2/(3.7*B2) + 5.74/G2^0.9))^2 Pump head (total dynamic head
Re: =F2*(B2/1000)/1e-6